Flat Wire |
SPT |
Stranded, Parallel, Thermoplastic. This is always followed by a -1, -2, or -3, signifying insulation thickness for different applications. |
HPN |
Heater, Parallel, Neoprene. Required for heater type applications, such as irons, toasters, etc. |
Jacketed Wire |
S |
Stranded (or service wire) |
J |
Junior Service (300 volts). If no "J" is in the wire type, then it is hard service (600 volts). |
T |
Thermoplastic. If no "T" is in the wire type, then it has a rubber jacket. |
O |
Oil resistant compound |
W |
CSA approved outdoor use (weather) |
W-A |
UL approved outdoor use (weather and atmosphere) |
V |
Vacuum - as in vacuum cleaner. This is a small O.D. jacketed wire, very flexible and initially used for vacuum cleaners. It is now used on many different types of end products. Available only in 18 AWG. |
Common Codes |
HPD |
Thermoset insulated heater cord with cotton braid overall. |
HPN |
Neoprene insulated heater cord. |
MTW |
Thermoplastic insulated machine tool wire. |
NM |
Non-metallic sheathed cable, multi-conductor building wire. |
R, RH |
Rubber insulated wire. Building wire used for construction |
S |
Extra hard service flexible cord for general use at 600 volts, rated at 60 C. Rubber insulated and jacketed. |
SE |
Extra hard service flexible cord for general use at 600 volts, rated at -58 F to +221F. TPE thermoplastic elastomer insulated and jacketed. |
SEO |
Type SE, but also rated oil resistant. |
SEOW |
Type SEO, but also rated for outdoor use at -58F. |
SEW |
Type SE, but additionally rated for outdoor use at -58 F. |
SJ |
Hard service cord for general use at 300 volts, rated at 60 C, rubber insulated and jacketed. |
SJE |
Hard service cord for general use at 300 volts, rated at -58 F to +221 F, TPE thermoplastic elastomer insulated and jacketed. |
SJEO |
Type SJE, but rated as oil resistant. |
SJEOW |
Type SJEO, but rated for outdoor use at -58 F. |
SJEW |
Type SJE, but rated for outdoor use at -58 F. |
SJO |
Type SJ, but rated oil resistant. |
SJOW |
Type SJO, but rated for outdoor use at -30 F. |
SJT |
Hard service cord for general use at 300 volts, rated -4 F to +140 F, PVC thermoplastic insulated and jacketed. |
SJTO |
Type SJT, but also rated oil resistant. |
SJTOW |
Type SJTO, but rated for outdoor use at -31 F. |
SJTW |
Type SJT, but rated or outdoor use at -31 F. |
SO |
Type S, but also rated oil resistant. |
HSJO |
Rubber insulated and jacketed. |
SPT-1 |
Thermoplastic parallel cord for light duty, 300 volts. |
SPT-2 |
Type SPT-1, but heavier construction, 300 volts. |
SPT-3 |
Type SPT-2, but heavier construction, 300 volts. |
ST |
Extra hard service cord for general use at 600 volts, rated at -4 F to +140 F, PVC thermoplastic insulated and jacketed. |
STO |
Type ST, but also rated oil resistant. |
STOW |
Type STO, but rated for outdoor use at -31F. |
STW |
Type ST, but rated for outdoor use at -31 F. |
SVT |
Vacuum cleaner cord, PVC thermoplastic insulated and jacketed rated 300 volts, 18 AWG and 16 AWG only, two conductors. |
T, TW, THN, THHN, THWN |
Thermoplastic insulated wires. Building wires used for construction. |
UF |
Thermoplastic underground feeder and branch circuit cable. Also used for submersible pump cable |